.. SPDX-License-Identifier: CC-BY-SA-4.0
|
|
|
|
.. Copyright (C) 1988, 2008 On-Line Applications Research Corporation (OAR)
|
|
|
|
Operations
|
|
==========
|
|
|
|
.. index:: _Terminate
|
|
|
|
.. _Terminate:
|
|
|
|
Announcing a Fatal Error
|
|
------------------------
|
|
|
|
The :c:func:`_Terminate()` internal error handler is invoked when the
|
|
application or the executive itself determines that a fatal error has occurred
|
|
or a final system state is reached (for example after :c:func:`rtems_fatal()`
|
|
or :c:func:`exit()`).
|
|
|
|
The first action of the internal error handler is to call the fatal extension of
|
|
the user extensions. For the initial extensions the following conditions are
|
|
required
|
|
|
|
- a valid stack pointer and enough stack space,
|
|
|
|
- a valid code memory, and
|
|
|
|
- valid read-only data.
|
|
|
|
For the initial extensions the read-write data (including .bss segment) is not
|
|
required on single processor configurations. In SMP configurations, however,
|
|
the read-write data must be initialized since this function must determine the
|
|
state of the other processors and request them to shut-down if necessary.
|
|
|
|
Non-initial extensions require in addition valid read-write data. The board
|
|
support package (BSP) may install an initial extension that performs a system
|
|
reset. In this case the non-initial extensions will be not called.
|
|
|
|
The fatal extensions are called with three parameters:
|
|
|
|
- the fatal source,
|
|
|
|
- a legacy parameter which is always set to :c:macro:`false`, and
|
|
|
|
- an error code with a fatal source dependent content.
|
|
|
|
Once all fatal extensions executed, the system state is set to
|
|
:c:macro:`SYSTEM_STATE_TERMINATED`.
|
|
|
|
The final step is to call the CPU port specific :c:func:`_CPU_Fatal_halt()`.
|